Fire Survival Cables
Fire Survival Cables

At Tamra Wires & Cables, we manufacture Fire Survival (FS) Cables designed to maintain circuit integrity during fire emergencies. Unlike ordinary flame-retardant cables, FS cables continue to carry power or signals for 90 to 180 minutes under fire conditions, ensuring uninterrupted operation of life-saving systems.

Tamra FS Cables are available with both Copper and Aluminium conductors, giving flexibility for cost-optimised and critical applications. Each conductor is wrapped with mica tape, followed by XLPE, EPR, or Silicone insulation, LSZH/FRLS sheathing, and optional armouring for enhanced protection.

Certified

Our FS Cables are tested and certified to:

  • IS 17505 (Part 1): 2021 – Circuit Integrity under Fire Conditions
  • IEC 60331 – Fire resistance tests
  • BS 6387 (CWZ tests) – Fire + Water + Mechanical Shock
  • BS 7846 / EN 50200 – Fire-resistant performance in buildings
Applications

Tamra Fire Survival Cables are widely used in:

Fire alarm, emergency lighting, and evacuation systems
Public address & communication circuits in metros, airports, tunnels
Power supply to fire pumps, sprinklers, lifts, smoke extraction fans
Refineries, petrochemicals, and hazardous plants
High-rise buildings, hospitals, and commercial complexes
Types & Sizes
  • BS 7846 / EN 50200 – Fire-resistant performance in buildings
Specification

IS17505 (Part -1) , IEC – 60331 , BS 6387 , BS – 7846 /EN 50200

Key Features
  • Copper & Aluminium conductor options
  • Circuit integrity 90–180 minutes at 750°C–950°C (IS 17505-1 / IEC 60331 / BS 6387 CWZ)
  • Low Smoke Zero Halogen (LSZH) or FRLS sheath for safe evacuation
  • Mica tape fire barrier over conductors
  • Fire resistance with fire + water + mechanical impact compliance
  • Suitable for both power and control circuits in critical installations
  • Designed for international and Indian standards compliance
Product Range

Fire Survival (FS) Cables improve safety, reduce fire damage to buildings and equipment, and provide critical extra time for evacuation during fire emergencies by maintaining circuit integrity under fire conditions.

Conductor
  • High-conductivity Copper or Aluminium
  • Solid / Stranded (Circular or Sector) / Flexible, Bare or Tinned
  • As per IS 8130 / IEC 60228
Insulation
  • PVC, XLPE, or EPR Rubber
  • With additional fire-resistant taping or screening as required
Fire Barrier
  • Layers of Mica Glass Tape applied directly over conductor (essential for fire survival performance)
Inner Sheath
  • PVC (FR/FRLS), PE, LSZH (Zero Halogen), or Rubber (FR/HOFR)
Armour (if required)
  • Galvanised Steel Wire / Strip (IS 3975)
  • Fibre Glass Braiding / Tapes for added fire & mechanical protection
Outer Sheath
  • Galvanised Steel Wire / Strip (IS 3975)
  • Fibre Glass Braiding / Tapes for added fire & mechanical protection